2″ATD & 3″ATDL – Automatic Angle models

General data

maximum working pressure: 10 Bar (145 psi)

Minimum backwash pressure: 2.0 Bar (29 psi)

Maximum working temperature: 60ºC (140ºF)

pH Range: 3 – 12

Row materials

Manifolds: HDPE

Filter housing and seals: Polyamide, NBR

Filter discs: Polypropylene

 

Technical specification

 

Number of filter units 2 x 2″ATD 3 x 2″ATD 4 x 2″ATD 2 x 3″ATDL 3 x 3″ATDL 4 x 3″ATDL 5 x 3″ATDL 6 x 3″ATDL
Maximum operating pressure 10 bar(145 psi)
Recommended backwash pressure >2.5 bar (36 psi)
Filtration Area

1960cm² (304in²)

2940cm² (456in²)  3920cm² (608in²)  2980cm² (462in²)  4470cm² (693in²)  5960cm² (924in²)  7450cm² (1155in²)  8940cm² (1386in²)
Inlet/Outlet manifolds (Universal Flnages)  90mm

(3″)

110mm

(4″)

110mm

(4″)

 110mm

(4″)

 110mm

(4″)

 110mm

(4″)

 160mm

(6″)

160mm

(6″)

Drain manifold (Universal Flange)  90mm

(3″)

 90mm

(3″)

Backwash flow rate  >7m³/h (31GPM) >10m³/h (44GPM)
Reccomended flow rate @130micron 27m³/h (119GPM) 40m³/h (176GPM)  54m³/h (238GPM)  40m³/h (176GPM) 60m³/h (264GPM) 80m³/h (352GPM) 100m³/h (440GPM)  120m³/h (528GPM)
Backwash volume per cycle (Flushing time per filter unit = 20sec) 78liters (20Gallons) 117liters (30Gallons) 155liters (40Gallons) 111liters (29Gallons) 167liters (44Gallons) 222liters (59Galons)  278liters (73Gallons) 333liters (88Galons)

Note: The reccomended flow rate is the Net flow rate after decreasing the backwash flow rate

 

System model A B C D E F Gross Weight Package Volume
2 x 2″ 629mm 846mm 476mm 163mm 150mm 390mm  73 Kg 0.7 cbm
3 x 2″ 904mm 846mm 476mm 163mm 150mm 390mm 0.9 cbm
4 x 2″ 1179mm 846mm 476mm 163mm 150mm 390mm 1.2 cbm
2 x 3″ 637mm 1033mm 562mm 210mm 182mm 466mm 83 Kg 0.7 cbm
3 x 3″ 912mm 1033mm 562mm 210mm 182mm 466mm 0.9 cbm
4 x 3″ 1217mm 1033mm 562mm 254mm 222mm 505mm 1.3 cbm
5 x 3″ 1490mm 1033mm 562mm 254mm 222mm 505mm 1.6 cbm
6 x 3″ 1765mm  1033mm 562mm 254mm  222mm 505mm 2.2 cbm